{"id":3834,"date":"2026-11-20T01:18:47","date_gmt":"2026-11-20T00:18:47","guid":{"rendered":"https:\/\/csibv.com\/blog\/hepa-vs-ulpa-filters-cleanroom\/"},"modified":"2026-11-20T01:18:49","modified_gmt":"2026-11-20T00:18:49","slug":"hepa-vs-ulpa-filter","status":"publish","type":"blog","link":"https:\/\/csibv.com\/de\/blog\/hepa-vs-ulpa-filter\/","title":{"rendered":"HEPA vs. ULPA: Unterschiede f\u00fcr Reinr\u00e4ume erkl\u00e4rt"},"author":5,"featured_media":3831,"parent":0,"menu_order":0,"template":"","meta":{"blog_intro":"<div class=\"translation-block nova-trp-field-beedfff7573e22eee6ad41ce86538c58\"><p>ULPA-filters houden nog fijnere deeltjes tegen dan HEPA-filters, maar die hogere filtratie gaat vrijwel altijd samen met meer drukverlies en dus zwaardere eisen aan het luchtbehandelingssysteem. De beste keuze is daarom niet automatisch het hoogste rendement op papier. Voor een goed cleanroomontwerp tellen ook de vereiste klasse, het procesrisico, het benodigde luchtdebiet en het energieverbruik mee. Belangrijk om meteen scherp te hebben: zowel HEPA als ULPA is bedoeld voor deeltjesfiltratie. Voor gassen, dampen en geuren zijn andere filtertechnieken nodig.<\/p><\/div>","blog_key_takeaways":["ULPA filtert fijner dan HEPA, maar veroorzaakt hoger drukverlies en vraagt meer van HVAC.","Kies op basis van ISO 14644-1 klasse, procesrisico en benodigd luchtdebiet, niet alleen op rendement.","HEPA (H13\u2013H14) is vaak de praktischere balans; ULPA (U15\u2013U17) is voor extreem kritische processen.","Hogere filterklassen be\u00efnvloeden ventilatorcapaciteit, energieverbruik en soms het benodigde filteroppervlak.","Onderhoud op gemeten drukverlies en integriteitstests; voor gassen en dampen zijn andere filtertechnieken nodig."],"blog_part_1":"<div class=\"translation-block nova-trp-source-3834\">\n<h2>Wat 99,97% en 99,999% technisch gezien betekenen<\/h2>\n<p>HEPA- en ULPA-filters zijn hoogrendementsfilters van fijne vezelmedia die zwevende deeltjes uit de lucht verwijderen. Dat gebeurt niet via \u00e9\u00e9n mechanisme, maar via een combinatie van interceptie, impactie en diffusie. Grotere deeltjes worden eerder uit de luchtstroom gehaald doordat ze door hun massa of baan niet netjes om de vezels heen bewegen. Zeer kleine deeltjes vertonen juist meer willekeurige beweging, waardoor ze alsnog op vezels botsen en blijven hangen.<\/p>\n<p>In de praktijk ziet u vaak referentiewaarden zoals HEPA rond 99,97% bij 0,3 \u00b5m en ULPA rond 99,999% bij 0,12 \u00b5m of 0,1 \u00b5m. ULPA heeft daarvoor een dichtere filterstructuur. Die genoemde deeltjesgrootte is geen harde ondergrens, maar een test- of referentiepunt rond de zogeheten MPPS: de meest doordringende deeltjesgrootte waarbij het filter relatief het minst effici\u00ebnt is. Voor zowel grotere als kleinere deeltjes kan de afvang juist hoger liggen. Beide filtertypen zijn dus bedoeld voor fijnstof en andere deeltjes, niet voor geur, gas of damp.<\/p>\n<h2>HEPA en ULPA naast elkaar: klassen en specificaties<\/h2>\n<p>Binnen EN 1822 worden HEPA- en ULPA-filters ingedeeld op hun prestatie bij de MPPS. In datasheets ziet u vaak effici\u00ebntie of penetratie; dat zijn elkaars spiegelbeeld.<\/p>\n<table>\n<thead>\n<tr>\n<th>Klasse<\/th>\n<th>Type<\/th>\n<th>Effici\u00ebntie bij MPPS<\/th>\n<th>Max. penetratie<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>H13<\/td>\n<td>HEPA<\/td>\n<td>\u2265 99,95%<\/td>\n<td>\u2264 0,05%<\/td>\n<\/tr>\n<tr>\n<td>H14<\/td>\n<td>HEPA<\/td>\n<td>\u2265 99,995%<\/td>\n<td>\u2264 0,005%<\/td>\n<\/tr>\n<tr>\n<td>U15<\/td>\n<td>ULPA<\/td>\n<td>\u2265 99,9995%<\/td>\n<td>\u2264 0,0005%<\/td>\n<\/tr>\n<tr>\n<td>U16<\/td>\n<td>ULPA<\/td>\n<td>\u2265 99,99995%<\/td>\n<td>\u2264 0,00005%<\/td>\n<\/tr>\n<tr>\n<td>U17<\/td>\n<td>ULPA<\/td>\n<td>\u2265 99,999995%<\/td>\n<td>\u2264 0,000005%<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>H13 en H14 zijn dus allebei HEPA, maar H14 laat maximaal tien keer minder deeltjes door dan H13. Ze zijn daarom niet zonder meer uitwisselbaar. In Amerikaanse documentatie wordt \u201cHEPA\u201d soms breder gebruikt; controleer dus altijd de exacte klasse en testbasis.<\/p>\n<\/div>","blog_part_2":"<div class=\"translation-block nova-trp-field-c202e58890d2dc1f2a0f27d80a3db267\"><h2>De impact op drukverlies, luchtdebiet en energieverbruik<\/h2>\n<p>Drukverlies is de weerstand die een filter veroorzaakt in de luchtstroom. Hoe dichter het filtermedium, hoe harder de ventilator moet werken om hetzelfde luchtdebiet te leveren. Omdat ULPA fijner filtreert, ligt die weerstand doorgaans hoger dan bij HEPA. Dat werkt direct door in ventilatorcapaciteit, benodigd filteroppervlak en het kunnen halen van het gewenste aantal luchtwisselingen of de vereiste luchtvolumestroom.<\/p>\n<p>In veel toepassingen biedt HEPA daarom de praktischere balans tussen deeltjesbeheersing en systeemprestatie. ULPA kan technisch noodzakelijk zijn, maar veroorzaakt sneller extra belasting op HVAC, meer energieverbruik en soms ook grotere of aangepaste filterplafonds. Zeker bij aanpassingen in bestaande cleanrooms is de beschikbare capaciteit van de installatie vaak een harde randvoorwaarde.<\/p>\n<h2>Welke filter past bij uw cleanroom en proces?<\/h2>\n<p>De juiste filterkeuze volgt uit de <a href=\"https:\/\/csibv.com\/blog\/iso-14644-1-cleanroom-classificatie\/\">ISO 14644-1 cleanroomclassificatie<\/a> en het werkelijke contaminatierisico van het proces, niet alleen uit het hoogste effici\u00ebntiecijfer. Een HEPA-filter is dus niet per definitie altijd nodig, en een ULPA-filter al helemaal niet. In veel farmaceutische, medische, food- en algemene productieomgevingen is een goed ontworpen HEPA-oplossing logisch, omdat die stabiele deeltjesbeheersing combineert met een werkbaar luchtdebiet en beheersbare systeembelasting.<\/p>\n<p>ULPA komt vooral in beeld bij semiconductor, micro-elektronica en vergelijkbaar kritische processen, waar strengere deeltjeslimieten of kleinere kritische deeltjes gelden. De uiteindelijke keuze moet aansluiten op de complete cleanroom: classificatie volgens de relevante norm, de luchtwisselingen en drukhi\u00ebrarchie zoals beschreven bij <a href=\"https:\/\/csibv.com\/blog\/cleanroom-overdruk-en-ventilatie\/\">Cleanroom overdruk en ventilatie<\/a>, lay-out, lekdichtheid en <a href=\"https:\/\/csibv.com\/blog\/validatie-vereisten-volgens-iso-14644-2\/\">Validatie-eisen volgens ISO 14644-2<\/a>. Daarom kijkt Cleanroom Systems International in het ontwerp niet alleen naar de filterklasse, maar naar de prestatie van het volledige gecontroleerde milieu.<\/p>\n<h2>Kosten, levensduur en onderhoud in de praktijk<\/h2>\n<ul>\n<li><strong>Totale kosten:<\/strong> HEPA is meestal gunstiger in aanschaf. ULPA is doorgaans duurder door de fijnere opbouw \u00e9n door hogere eisen aan ventilatoren, filteroppervlak en energieverbruik.<\/li>\n<li><strong>Levensduur:<\/strong> ULPA kan in de praktijk sneller dichtlopen bij dezelfde deeltjesbelasting. Daardoor zijn controle en vervanging vaak eerder nodig dan bij een vergelijkbare HEPA-toepassing.<\/li>\n<li><strong>Vervangingsmoment:<\/strong> vervang niet alleen op kalenderdatum. Voorfiltratie, gebruiksuren, vervuilingsgraad en gemeten drukverlies bepalen samen het juiste interval.<\/li>\n<li><strong>Onderhoud:<\/strong> een HEPA-filter in een kritische cleanroom is normaal geen onderdeel om zelf schoon te maken. Inspectie, een <a href=\"https:\/\/csibv.com\/blog\/hepa-filter-integriteitstest\/\">HEPA-filter integriteitstest<\/a> en vervanging horen thuis in een onderhouds- en validatieplan volgens de eisen van uw proces en ruimte. Leg de meetstrategie en acties vast in een <a href=\"https:\/\/csibv.com\/blog\/cleanroom-monitoring-plan\/\">Cleanroom monitoringplan<\/a>.<\/li>\n<\/ul><\/div>","blog_faqs":[{"question":"Wat is het verschil tussen HEPA en ULPA?","answer":"<p>HEPA (H13\u2013H14) en ULPA (U15\u2013U17) zijn hoogrendements deeltjesfilters. ULPA heeft een hogere effici\u00ebntie (fijnere afvang) dan HEPA, maar veroorzaakt ook meer drukverlies. Beide zijn bedoeld voor deeltjesfiltratie; voor gassen, dampen en geuren zijn andere filtertechnieken vereist.<\/p>"},{"question":"Wat betekent 99,97% bij 0,3 \u00b5m en wat is MPPS?","answer":"<p>De waarde 99,97% (typisch voor HEPA) en 99,999% (typisch voor ULPA) wordt vaak opgegeven bij een testdeeltjesgrootte rond de MPPS: de meest doordringende deeltjesgrootte. Het is geen ondergrens; voor zowel grotere als kleinere deeltjes kan de afvang hoger liggen.<\/p>"},{"question":"Heeft ULPA altijd de voorkeur boven HEPA?","answer":"<p>Niet per se. ULPA biedt fijnere filtratie, maar verhoogt drukverlies en energieverbruik en kan aanpassingen aan HVAC en filteroppervlak vereisen. In veel toepassingen is HEPA de betere balans; ULPA is vooral zinvol in zeer kritische omgevingen zoals semiconductor en micro-elektronica.<\/p>"},{"question":"Welke filterklasse heb ik nodig voor mijn cleanroom?","answer":"<p>De keuze volgt uit uw <a href=\"https:\/\/csibv.com\/blog\/iso-14644-1-cleanroom-classificatie\/\">ISO 14644-1 classificatie<\/a>, procesrisico, benodigd luchtdebiet en systeemprestaties. Kijk niet alleen naar het hoogste rendement, maar naar de prestaties van het volledige gecontroleerde milieu.<\/p>"},{"question":"Wanneer vervang ik filters en hoe borg ik onderhoud?","answer":"<p>Vervang op basis van gemeten drukverlies, vervuilingsgraad, gebruiksuren en voorfiltratie in plaats van uitsluitend kalendergestuurd. Voer periodieke integriteitstests uit (zie <a href=\"https:\/\/csibv.com\/blog\/hepa-filter-integriteitstest\/\">HEPA-filter integriteitstest<\/a>) en leg meetstrategie en acties vast in een <a href=\"https:\/\/csibv.com\/blog\/cleanroom-monitoring-plan\/\">cleanroom monitoringplan<\/a>.<\/p>"}]},"class_list":["post-3834","blog","type-blog","status-publish","has-post-thumbnail","hentry"],"acf":[],"meta_descriptions":{"blog_intro":"Intro paragraph shown directly beneath the author\/meta row. Keep this concise (maximum 100 words).","blog_key_takeaways":"Key takeaways\/TLDR bullet list (array of strings). Populate this with concise, scannable points (recommended 3-5 bullets).","blog_part_1":"First rich-text section after the intro. Keep this to roughly 40% of the remaining article content. Do not place the majority of body content here.","blog_part_2":"Second rich-text section after the intro. Put the remaining roughly 60% of post-intro content here. This must contain the majority of the article body and should be longer than blog_part_1.","blog_faqs":"FAQ items shown in the FAQ section ({question,answer}[]). Add FAQs here so they render as proper accordion items. Do not repeat FAQ content in blog_part_1 or blog_part_2."},"meta_note":"Write the intro in up to 100 words. After the intro, split the remaining body content as roughly 40% in blog_part_1 and 60% in blog_part_2. Keep blog_part_1 shorter; blog_part_2 must be the longer section. Populate blog_key_takeaways with concise key points (recommended 3-5 bullets). Place FAQ items in blog_faqs so they render as proper FAQ accordions; do not duplicate those FAQs in blog_part_1 or blog_part_2. Auto-generated sections (table of contents and default related articles) and CTA fields are intentionally excluded from this payload. Fields for disabled components are omitted from meta and meta_descriptions.","meta_all":[],"meta_all_flat":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>HEPA vs ULPA-filters voor cleanrooms<\/title>\n<meta name=\"description\" content=\"Ontdek het verschil tussen HEPA en ULPA voor cleanrooms: filtratie, drukverlies, energieverbruik, toepassingen, kosten en onderhoud.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/csibv.com\/de\/blog\/hepa-vs-ulpa-filter\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HEPA vs ULPA-filters voor cleanrooms\" \/>\n<meta property=\"og:description\" content=\"Ontdek het verschil tussen HEPA en ULPA voor cleanrooms: filtratie, drukverlies, energieverbruik, toepassingen, kosten en onderhoud.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/csibv.com\/de\/blog\/hepa-vs-ulpa-filter\/\" \/>\n<meta property=\"og:site_name\" content=\"Cleanroom Systems International B.V.\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-20T00:18:49+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/csibv.com\/wp-content\/uploads\/2026\/01\/logo_CSI.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1391\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/csibv.com\\\/blog\\\/hepa-vs-ulpa-filters-cleanroom\\\/\",\"url\":\"https:\\\/\\\/csibv.com\\\/blog\\\/hepa-vs-ulpa-filters-cleanroom\\\/\",\"name\":\"HEPA vs ULPA-filters voor cleanrooms\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/csibv.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/csibv.com\\\/blog\\\/hepa-vs-ulpa-filters-cleanroom\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/csibv.com\\\/blog\\\/hepa-vs-ulpa-filters-cleanroom\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/csibv.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/hepa-vs-ulpa-image1.jpg\",\"datePublished\":\"2026-11-20T00:18:47+00:00\",\"dateModified\":\"2026-11-20T00:18:49+00:00\",\"description\":\"Ontdek het verschil tussen HEPA en ULPA voor cleanrooms: filtratie, drukverlies, energieverbruik, toepassingen, kosten en onderhoud.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/csibv.com\\\/blog\\\/hepa-vs-ulpa-filters-cleanroom\\\/#breadcrumb\"},\"inLanguage\":\"de-DE\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/csibv.com\\\/blog\\\/hepa-vs-ulpa-filters-cleanroom\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de-DE\",\"@id\":\"https:\\\/\\\/csibv.com\\\/blog\\\/hepa-vs-ulpa-filters-cleanroom\\\/#primaryimage\",\"url\":\"https:\\\/\\\/csibv.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/hepa-vs-ulpa-image1.jpg\",\"contentUrl\":\"https:\\\/\\\/csibv.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/hepa-vs-ulpa-image1.jpg\",\"width\":1024,\"height\":1024,\"caption\":\"HEPA vs ULPA-filters voor cleanrooms\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/csibv.com\\\/blog\\\/hepa-vs-ulpa-filters-cleanroom\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/csibv.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blogs\",\"item\":\"https:\\\/\\\/csibv.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"HEPA vs ULPA-filters voor cleanrooms\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/csibv.com\\\/#website\",\"url\":\"https:\\\/\\\/csibv.com\\\/\",\"name\":\"Cleanroom Systems International B.V.\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/csibv.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/csibv.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de-DE\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/csibv.com\\\/#organization\",\"name\":\"Cleanroom Systems International B.V.\",\"url\":\"https:\\\/\\\/csibv.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de-DE\",\"@id\":\"https:\\\/\\\/csibv.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/csibv.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/logo_CSI.png\",\"contentUrl\":\"https:\\\/\\\/csibv.com\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/logo_CSI.png\",\"width\":1391,\"height\":450,\"caption\":\"Cleanroom Systems International B.V.\"},\"image\":{\"@id\":\"https:\\\/\\\/csibv.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HEPA vs. ULPA: Unterschiede f\u00fcr Reinr\u00e4ume erkl\u00e4rt","description":"HEPA oder ULPA? Erfahren Sie, wie sich Filterklassen, MPPS, Druckverlust und Reinraumkonzept auf die richtige Auswahl im Projekt auswirken.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/csibv.com\/de\/blog\/hepa-vs-ulpa-filter\/","og_locale":"de_DE","og_type":"article","og_title":"HEPA vs ULPA-filters voor cleanrooms","og_description":"Ontdek het verschil tussen HEPA en ULPA voor cleanrooms: filtratie, drukverlies, energieverbruik, toepassingen, kosten en onderhoud.","og_url":"https:\/\/csibv.com\/de\/blog\/hepa-vs-ulpa-filter\/","og_site_name":"Cleanroom Systems International B.V.","article_modified_time":"2026-11-20T00:18:49+00:00","og_image":[{"width":1391,"height":450,"url":"https:\/\/csibv.com\/wp-content\/uploads\/2026\/01\/logo_CSI.png","type":"image\/png"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/csibv.com\/blog\/hepa-vs-ulpa-filters-cleanroom\/","url":"https:\/\/csibv.com\/blog\/hepa-vs-ulpa-filters-cleanroom\/","name":"HEPA vs. ULPA: Unterschiede f\u00fcr Reinr\u00e4ume erkl\u00e4rt","isPartOf":{"@id":"https:\/\/csibv.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/csibv.com\/blog\/hepa-vs-ulpa-filters-cleanroom\/#primaryimage"},"image":{"@id":"https:\/\/csibv.com\/blog\/hepa-vs-ulpa-filters-cleanroom\/#primaryimage"},"thumbnailUrl":"https:\/\/csibv.com\/wp-content\/uploads\/2026\/11\/hepa-vs-ulpa-image1.jpg","datePublished":"2026-11-20T00:18:47+00:00","dateModified":"2026-11-20T00:18:49+00:00","description":"HEPA oder ULPA? Erfahren Sie, wie sich Filterklassen, MPPS, Druckverlust und Reinraumkonzept auf die richtige Auswahl im Projekt auswirken.","breadcrumb":{"@id":"https:\/\/csibv.com\/blog\/hepa-vs-ulpa-filters-cleanroom\/#breadcrumb"},"inLanguage":"de-DE","potentialAction":[{"@type":"ReadAction","target":["https:\/\/csibv.com\/blog\/hepa-vs-ulpa-filters-cleanroom\/"]}]},{"@type":"ImageObject","inLanguage":"de-DE","@id":"https:\/\/csibv.com\/blog\/hepa-vs-ulpa-filters-cleanroom\/#primaryimage","url":"https:\/\/csibv.com\/wp-content\/uploads\/2026\/11\/hepa-vs-ulpa-image1.jpg","contentUrl":"https:\/\/csibv.com\/wp-content\/uploads\/2026\/11\/hepa-vs-ulpa-image1.jpg","width":1024,"height":1024,"caption":"HEPA vs ULPA-filters voor cleanrooms"},{"@type":"BreadcrumbList","@id":"https:\/\/csibv.com\/blog\/hepa-vs-ulpa-filters-cleanroom\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/csibv.com\/"},{"@type":"ListItem","position":2,"name":"Blogs","item":"https:\/\/csibv.com\/blog\/"},{"@type":"ListItem","position":3,"name":"HEPA vs ULPA-filters voor cleanrooms"}]},{"@type":"WebSite","@id":"https:\/\/csibv.com\/#website","url":"https:\/\/csibv.com\/","name":"Reinraum-Systeme International B.V.","description":"","publisher":{"@id":"https:\/\/csibv.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/csibv.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de-DE"},{"@type":"Organization","@id":"https:\/\/csibv.com\/#organization","name":"Reinraum-Systeme International B.V.","url":"https:\/\/csibv.com\/","logo":{"@type":"ImageObject","inLanguage":"de-DE","@id":"https:\/\/csibv.com\/#\/schema\/logo\/image\/","url":"https:\/\/csibv.com\/wp-content\/uploads\/2026\/01\/logo_CSI.png","contentUrl":"https:\/\/csibv.com\/wp-content\/uploads\/2026\/01\/logo_CSI.png","width":1391,"height":450,"caption":"Cleanroom Systems International B.V."},"image":{"@id":"https:\/\/csibv.com\/#\/schema\/logo\/image\/"}}]}},"_links":{"self":[{"href":"https:\/\/csibv.com\/de\/wp-json\/wp\/v2\/blog\/3834","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/csibv.com\/de\/wp-json\/wp\/v2\/blog"}],"about":[{"href":"https:\/\/csibv.com\/de\/wp-json\/wp\/v2\/types\/blog"}],"author":[{"embeddable":true,"href":"https:\/\/csibv.com\/de\/wp-json\/wp\/v2\/users\/5"}],"version-history":[{"count":1,"href":"https:\/\/csibv.com\/de\/wp-json\/wp\/v2\/blog\/3834\/revisions"}],"predecessor-version":[{"id":3835,"href":"https:\/\/csibv.com\/de\/wp-json\/wp\/v2\/blog\/3834\/revisions\/3835"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/csibv.com\/de\/wp-json\/wp\/v2\/media\/3831"}],"wp:attachment":[{"href":"https:\/\/csibv.com\/de\/wp-json\/wp\/v2\/media?parent=3834"}],"curies":[{"name":"Welt","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}